View Issue Details

IDProjectCategoryView StatusLast Update
0000515T99X171.00 SKB EagleHWpublic2019-03-28 11:56
Reporter(ALTech) SB ParkAssigned To(PM) Sheila Tu Due Date2019-02-26 22:15
PrioritynormalSeveritys2-severeReproducibilityN/A
Status closedResolutionfixed 
Summary0000515: SKB's profile of temperature and humidity test
DescriptionSKB's recommend to their own temperature and humidity test's criteria

1. Input condition
    1) voltage : 220v
    2) Source : SKB's Live channel in their network
2. Test sample quantity : 6ea
    1) DUT1, 2 : MultiView
    2) DUT3, 4 : VOD
    3) DUT5, 6 : UHD (Umax)
3. chamber temperature and humidity profiel
    1) See the attached file
4. template of test result
    1) See the attached file
TagsNo tags attached.
Attach Tags

Relationships

related to 0000510 closed(HW) Sean Chiang [EAGLE] SKB's specification of Temperature/Humidity test standard 
related to 0000494 closed(PM) Sheila Tu DUT Quantity at reliability test 

Users monitoring this issue

User List (ALTech) Philip , (ALTech) SB Park , (ALTech) SY Yoon , (HW) Sean Chiang , (RD) Fu-chiang Young

Activities

(ALTech) SB Park

2019-02-25 21:29

developer  

(ALTech) SB Park

2019-02-25 21:34

developer   ~0001198

Hi Sheila
You gave me to T99X171.00 Reliability test plan v4.0.
please update the SKB's criteria of temp and humidity at your document.

(PM) Sheila Tu

2019-02-27 10:25

developer   ~0001225

The test streaming will be a problem because the network speed is too slow.
Is it possible that ALT provides any fix streaming to test?

(ALTech) SB Park

2019-02-28 09:21

developer   ~0001244

connect below site

https://www.youtube.com/watch?v=PLUCPudeFTs

https://www.youtube.com/watch?v=uRTf0lCcP0c

https://www.youtube.com/watch?v=mS4QqjObuXM

https://www.youtube.com/watch?v=68mAtn7R5Mg

(ALTech) SB Park

2019-03-15 21:37

developer   ~0001566

SKB request to the low temperature set -5 degree (not 0 degree)

(PM) Sheila Tu

2019-03-18 11:31

developer   ~0001576

Please explain in detail why SKB requires to change the low temperature?

(ALTech) SB Park

2019-03-18 12:05

developer   ~0001579

it is their criteria

(PM) Sheila Tu

2019-03-18 13:18

developer   ~0001580

Does it write in their RFP? I think we have confirmed the test criteria with you many times.

(ALTech) SB Park

2019-03-18 13:26

developer   ~0001581

We discuss about high temperature. and I heard that FXN want to know the low temperature from Mr. Philip. So I asked SKB about low temperature. SKB comment that low temperature is -5 degree.

(HW) Sean Chiang

2019-03-25 15:22    private

developer   ~0001692

Hi SB,
Please find attached for the updated reliability test plan.
The high/low temp. spec. has been updated and also including SKB temperature&humidity profile in item7 of climate test.
Please reivew it and let us know if any further questions from SKB.

(ALTech) SB Park

2019-03-25 15:52

developer   ~0001695

Hi Sean
Good job.
but check again the below :
1. Mechanical test. 4. Remote Control Display Angle should be changed to SKB's spec.
2. Mechanical test. 5. Abrasion Resistance of Label test should be changed to SKB's spec. (50 degree)

(PM) Sheila Tu

2019-03-27 23:13

developer   ~0001757

Hi SB, please find the attached file for the reliability test plan.
Because we'll proceed to the preparation from 4/1, please help to fix the test plan by 3/30. Thank you.

(ALTech) SB Park

2019-03-28 11:56

developer   ~0001758

Hi Sheila. Good job thank you.

Issue History

Date Modified Username Field Change
2019-02-25 21:29 (ALTech) SB Park New Issue
2019-02-25 21:29 (ALTech) SB Park Status new => assigned
2019-02-25 21:29 (ALTech) SB Park Assigned To => (PM) Sheila Tu
2019-02-25 21:29 (ALTech) SB Park File Added: SKB_temp_humi_profile.pptx
2019-02-25 21:30 (ALTech) SB Park Issue Monitored: (ALTech) SB Park
2019-02-25 21:30 (ALTech) SB Park Issue Monitored: (ALTech) SY Yoon
2019-02-25 21:31 (ALTech) SB Park Issue Monitored: (HW) Sean Chiang
2019-02-25 21:34 (ALTech) SB Park Note Added: 0001198
2019-02-27 10:25 (PM) Sheila Tu Status assigned => feedback
2019-02-27 10:25 (PM) Sheila Tu Note Added: 0001225
2019-02-28 09:21 (ALTech) SB Park Note Added: 0001244
2019-02-28 09:21 (ALTech) SB Park Status feedback => assigned
2019-03-04 13:52 (HW) Sean Chiang Issue Monitored: (RD) Fu-chiang Young
2019-03-15 21:37 (ALTech) SB Park Issue Monitored: (ALTech) Philip
2019-03-15 21:37 (ALTech) SB Park Note Added: 0001566
2019-03-18 11:31 (PM) Sheila Tu Note Added: 0001576
2019-03-18 12:05 (ALTech) SB Park Note Added: 0001579
2019-03-18 13:18 (PM) Sheila Tu Note Added: 0001580
2019-03-18 13:26 (ALTech) SB Park Note Added: 0001581
2019-03-25 15:22 (HW) Sean Chiang File Added: T99X171.00 Reliability test plan v4.0_20190322.xlsx
2019-03-25 15:22 (HW) Sean Chiang Note Added: 0001692
2019-03-25 15:46 (HW) Sean Chiang Note View State: 0001692: private
2019-03-25 15:52 (ALTech) SB Park Note Added: 0001695
2019-03-25 15:56 System Admin File Deleted: T99X171.00 Reliability test plan v4.0_20190322.xlsx
2019-03-27 23:07 (PM) Sheila Tu Relationship added related to 0000510
2019-03-27 23:08 (PM) Sheila Tu Relationship added related to 0000494
2019-03-27 23:13 (PM) Sheila Tu File Added: T99X171.00 Reliability test plan v5.0_20190327v1.pdf
2019-03-27 23:13 (PM) Sheila Tu Note Added: 0001757
2019-03-28 11:56 (ALTech) SB Park Note Added: 0001758
2019-03-28 11:56 (ALTech) SB Park Status assigned => closed
2019-03-28 11:56 (ALTech) SB Park Resolution open => fixed